   CET850
   Copyright (C) 2011 - 2024
   Schneider Electric Industries SAS
   All Rights Reserved

-------------------------------------------------------------------------------

-------------------------------------------------------------------------------
1. Use of CET850

2. CET850 general presentation

3. Version history

4. Contact Schneider Electric


-------------------------------------------------------------------------------
1. Use of CET850
-------------------------------------------------------------------------------

>> Warning
------------------
CET850 v4.13 completely replaces previous versions. 
You must not overwrite CET850 v3.0 or upper versions with CET850 v2.0(v1.0)

>> Warning - SEPAM range
------------------------
The Indexed Report Control Blocks are not supported by ACE850 versions before v1.2 
and ECI850 versions before v1.25.

>> Starting CET850
------------------
The installation program creates automatically both a CET850 shortcut in the program
group chosen during the setup (Program group Schneider Electric by default)
and a CET850 shortcut on the desktop.

Run the program either from the Start menu or from the desktop.
Consult the Help menu of the program, if necessary.

>> Language selection
---------------------
There is a choice of 3 applications language for CET850:
English-US, French and Spanish.
The application language is chosen during setup.

To modify the language later:
1. Run the CET850 software
2. Select the wished language in Tools menu of CET850
3. Exit and then restart the CET850


-------------------------------------------------------------------------------
2. CET850 general presentation
-------------------------------------------------------------------------------

CET850 is the IEC 61850 configurator associated with the Sepam devices
and the ECI850 Sepam server.

The CET850 software enables protection and integration engineers to design
automated substations containing Schneider Electric Intelligent Electronic Devices
(IED) compliant with the IEC 61850 Standard.

CET850 provides a set of functions to create, edit, and display IEC 61850
configuration files based on the Substation Configuration Language (SCL)
in conformance with IEC 61850 part 6.

CET850 deals with the following SCL files:
- ICD files: IED Capabilities Description
- IID files: Instantiated IED Description
- CID files: Configured IED Description
- SCD files: Substation Configuration Description

CET850 is delivered with a library of ICD files that provides the IEC 61850 description
of the Schneider Electric Sepam, ION7x50, ION8650 and G3200 range IEDs.

CET850 can be used to:
- Create an IEC 61850 configuration or modifying an existing one by adding Sepam IEDs
  using their ICD file.
- Edit an SCL file (ICD, IID, CID or SCD) to modify its contents:
    > Display the device and system configuration
    > Add or remove IEDs
    > Set or modify the communication parameter values
    > Optimize the configuration by creating or modifying
      Datasets, Report Control Blocks and Goose Control Blocks.

- Generate the CID file for storing the configuration of one IED,
  which can then be downloaded to the devices via FTP protocol
  , or SFT2841 Sepam commissioning tool for SEPAMs only.

- Generate an IID file for storing the configuration of an IED which
  can then be used by other IEC 61850 configuration tools.

- Generate an SCD file for storing the configuration of an IEC 61850 system which
  can then be used by other IEC 61850 configuration tools.

CET850 enables the optimization of data transferred within the system by:
- Creating or adapt DataSets to gather relevant data
- Creating or adapt Report Control Blocks to define the transmission conditions
- Setting deadband values for sending measurements reports
- Creating or adapt Goose Control Blocks to define the peer-to-peer data exchange
  based on the producer/consumer communication model.

The configuration of peer-to-peer communication between Sepam devices (Goose messaging)
is available to implement specific distributed protection and control functions
like inter-locking, inter-tripping, logic discrimination, ...
 
CET850 is delivered with a library ICD files for all devices range IEDs.
ICD files from other manufacturers may be used, and IID, SCD and CID files coming from other
IEC 61850 configuration tools may be edited with CET850.
Nevertheless, some specific editing features are restricted to Schneider Electric IEDs. 


-------------------------------------------------------------------------------
3. Version history
-------------------------------------------------------------------------------

Version 1.0
   - Initial release
   - Compliant with IEC 61850 Edition 1.
   - Opened to SEPAMs, IONs meters and G3200 server. 

Version 2.0
   - Compliant with IEC 61850 Edition 1 and Edition 2.
   - Opened to IONs meters and G3200 server in Edition 1.
   - Opened to SEPAMs in Edition 1 and Edition2.
 
Version 3.0
   - Compliant with IEC 61850 Edition 1 and Edition 2.0 (2007B).

Version 3.2
   - Support of IEC 61850 Engineering Workflow for Easergy P5.
   - Support of IEC 61850 Engineering Workflow for Easergy P3.
   - Automatic binding for GOOSE message data for SEPAM, Easergy P3 and Easergy P5.
   - Compatibility with Schneider Electric EcoStruxure Grid Engineering Advisor (IEC 61850 System Engineering Tool).
   - Automatic processing during SCD file import (automatic binding, CID generation).

Version 3.3
   - Support of IEC 61850 Engineering Workflow for Easergy P5 V01.3xx.
   - Support of IEC 61850 Engineering Workflow for MasterPact MTZ.

Version 3.6
   - Update for Easergy P5 V01.3xx.

Version 4.0
   - Support of IEC 61850 Engineering Workflow for Easergy P5 V01.4xx.

Version 4.1
   - Update for Easergy P5 V01.4xx.

Version 4.2
   - Update for Easergy P5 with LN LGOS.
   
Version 4.3
   - Bug fixes.

Version 4.4
   - "PowerLogic P5" replaces "Easergy P5
   - Bug fixes.

Version 4.5
   - Support of IEC 61850 Engineering Workflow for PowerLogic P5 V01.5xx
   - Bug fixes.

Version 4.6
   - Adding subscription to Data Object (DO) (PowerLogic P5 V02.501).
   - Adding multiple Logical Device (LD) feature (PowerLogic P5 V02.501).
   - Bug fixes.

Version 4.7
   - Adding SCL Edition 2.1 (2007B4) for PowerLogic P5 V02.501.
   - Bug fixes.

Version 4.8
   - Support of IEC 61850 Engineering Workflow for PowerLogic P3x6x V01.100.
   - Bug fixes

Version 4.9
   - Bug fixes.

Version 4.10
   - Bug fixes.

Version 4.11
   - Adding ICD files for PowerLogic P5 V02.501.
   - Adding ICD files for PowerLogic P3x6x V01.100.
   - Bug fixes.

Version 4.12
   - Updating ICD files for PowerLogic P5 V02.501.
   - Bug fixes.

Version 4.13
   - Updating ICD files for PowerLogic P3x6x V01.100.
   - Bug fixes.

-------------------------------------------------------------------------------
4. Contact Schneider Electric
-------------------------------------------------------------------------------

   Schneider Electric Industries SAS
   35 rue Joseph Monier
   92500 Rueil-Malmaison
   FRANCE
   Phone: +33 (0) 1 41 29 70 00
   Fax:   +33 (0) 1 41 29 71 00

   Internet:  https://www.se.com/ww/en/