; 7330 ION Rev B Setup Assistant [SetupInfo] SetupScreens=1 Screen1=Setup Assistant [Setup Assistant] AssistantText=Welcome to the Setup Assistant! The following dialogs guide you through device setup. Select from the left which setup you wish to perform or press the Next button to cycle through all of the different setups. AssistantCount=11 Assistant1=Template Assistant2=Basic Setup Assistant3=Comm Settings Assistant4=3rd Party Protocols Assistant5=Clock Assistant6=Demand Assistant7=Energy Pulsing Assistant8=Analog Outputs Assistant9=Memory Assistant10=EnergyDemand Log Assistant11=Reports PrintList=0,7,15,0,1,1,15,15,1,3 [Template] TabCount=4 Tab1=Save to PC Tab1Type=2 Tab1Text=You can save the meter's entire configuration and store it to a .DCF file. You need this file when you upgrade the meter firmware, or you can send the .DCF file onto other ION meters of the same type. Tab1Buttons=1 Tab1Button1Label=Save Tab1Button1=1,1 Tab1Registers=4 Tab1Reg1=3,1,0x1300 Tab1Reg2=3,1,0x1303 Tab1Reg3=3,1,0x1304 Tab1Reg4=3,1,0x137D Tab2=Send to Meter Tab2Type=2 Tab2Text=Sends a previously stored meter configuration file (.DCF) into an ION meter. Tab2Buttons=1 Tab2Button1Label=Send Tab2Button1=1,2 Tab2Registers=4 Tab2Reg1=3,1,0x1300 Tab2Reg2=3,1,0x1303 Tab2Reg3=3,1,0x1304 Tab2Reg4=3,1,0x137D Tab3=Firmware Upgrade Tab3Type=2 Tab3Text=To get new features for your meter, you can upgrade a meter's firmware to a newer version. NOTE: You must specify a .DCF, or device configuration file. If you do not have one, use the Save to PC tab to create a file of your meter's present configuration. Tab3Buttons=1 Tab3Button1Label=Upgrade Tab3Button1=1,3 Tab3Registers=4 Tab3Reg1=3,1,0x1300 Tab3Reg2=3,1,0x1303 Tab3Reg3=3,1,0x1304 Tab3Reg4=3,1,0x137D Tab4Firmware=270 Tab4=Register Edit Tab4Type=2 Tab4Text=Allows you to view and modify energy register values Tab4Buttons=1 Tab4Button1Label=Display Tab4Button1=0,8 Tab4Registers=1 Tab4Reg1=11,1,Energy Tab4Reg1Groups=3 Tab4Reg1Group1Label=kWh Tab4Reg1Group2Label=kVARh Tab4Reg1Group3Label=kVAh Tab4Reg1Group1Displays=4 Tab4Reg1Group1Display1=0x58B0 Tab4Reg1Group1Display1Label=Imported Tab4Reg1Group1Display2=0x58B1 Tab4Reg1Group1Display2Label=Exported Tab4Reg1Group1Display3=0x58B2 Tab4Reg1Group1Display3Label=Total Tab4Reg1Group1Display4=0x58B3 Tab4Reg1Group1Display4Label=Net Tab4Reg1Group2Displays=4 Tab4Reg1Group2Display1=0x58B4 Tab4Reg1Group2Display1Label=Imported Tab4Reg1Group2Display2=0x58B5 Tab4Reg1Group2Display2Label=Exported Tab4Reg1Group2Display3=0x58B6 Tab4Reg1Group2Display3Label=Total Tab4Reg1Group2Display4=0x58B7 Tab4Reg1Group2Display4Label=Net Tab4Reg1Group3Displays=4 Tab4Reg1Group3Display1=0x58B8 Tab4Reg1Group3Display1Label=Imported Tab4Reg1Group3Display2=0x58B9 Tab4Reg1Group3Display2Label=Exported Tab4Reg1Group3Display3=0x5FA1 Tab4Reg1Group3Display3Label=Total Tab4Reg1Group3Display4=0x5FA2 Tab4Reg1Group3Display4Label=Net [Basic Setup] TabCount=3 Tab1=PT/CT Ratios Tab1Type=2 Tab1Text=Allows you to program PT and CT ratios. Tab1Buttons=1 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Registers=5 Tab1Reg1=1,1,0x7800 Tab1Reg1Text=This is the meter operating mode. Tab1Reg2=0,1,0x7000 Tab1Reg2Text=This is the primary rating for the meter potential transformers. Tab1Reg3=0,1,0x7001 Tab1Reg3Text=This is the secondary rating for the meter potential transformers. Tab1Reg4=0,1,0x7002 Tab1Reg4Text=This is the primary rating for the meter current transformers. Tab1Reg5=0,1,0x7003 Tab1Reg5Text=This is the secondary rating for the meter current transformers. Tab2=Nameplate Info Tab2Type=2 Tab2Text=Allows you to program meter nameplate information. Tab2Buttons=1 Tab2Button1Label=Edit Tab2Button1=0,4 Tab2Registers=8 Tab2Reg1=3,0,0x1300 Tab2Reg2=3,0,0x1303 Tab2Reg3=3,0,0x1304 Tab2Reg4=3,1,0x137D Tab2Reg4Text=This is where you can program the meter template string. NOTE: Modifying this value manually may cause some functions to not operate properly and should only be done by advanced users. Tab2Reg5=3,0,0x1302 Tab2Reg6=3,1,0x1345 Tab2Reg6Text=This is where you can program the meter owner (utility) information. Tab2Reg7=3,1,0x1346 Tab2Reg7Text=This is where you can program the meter location (customer) information. Tab2Reg8=3,1,0x1347 Tab2Reg8Text=This is where you can program the meter identification information. NOTE: If this field is not blank, MV-90 requires their Device ID field to match this field. Tab3=Rollover Tab3Type=2 Tab3Text=Allows you to program energy rollover information. Tab3Buttons=1 Tab3Button1Label=Edit Tab3Button1=0,4 Tab3Registers=1 Tab3Reg1=0,1,0x721E Tab3Reg1Warning=1 Tab3Reg1Text=This specifies the reading at which energy values will reset back to zero. NOTE: Values of 10 million or lower are recommended for resolution purposes. Tab3Reg1Multi=1 Tab3Reg1Label=Energy Rollover [Comm Settings] TabCount=4 Tab1=Com1 Tab1Type=2 Tab1Text=Allows you to modify the Com1 communication settings. Tab1Buttons=1 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Registers=4 Tab1Reg1=1,1,0x7A4F Tab1Reg1Text=This specifies which communication protocol is active (Must be Modemgate if modem is installed). Tab1Reg2=0,1,0x71E9 Tab1Reg2Text=This specifies the unit ID used to identify the meter during communications. Tab1Reg3=1,1,0x7987 Tab1Reg3Text=This specifies the comm port baud rate used during serial communications. Tab1Reg4=3,1,0x5050 Tab1Reg4Text=This specifies the modem initialization string used if a modem is present. Tab2=Com2 Tab2Type=2 Tab2Text=Allows you to modify the Com2 communication settings. Tab2Buttons=1 Tab2Button1Label=Edit Tab2Button1=0,4 Tab2Registers=3 Tab2Reg1=1,1,0x7A50 Tab2Reg1Text=This specifies which communication protocol is active (Must be Ethergate if Ethernet is installed). Tab2Reg2=0,1,0x7234 Tab2Reg2Text=This specifies the unit ID used to identify the meter during communications. Tab2Reg3=1,1,0x7A4D Tab2Reg3Text=This specifies the baud rate used during serial communications. Tab3=Optical Tab3Type=2 Tab3Text=Allows you to modify the ANSI optical port communication settings. Tab3Buttons=1 Tab3Button1Label=Edit Tab3Button1=0,4 Tab3Registers=3 Tab3Reg1=1,1,0x7A51 Tab3Reg1Text=This specifies which communication protocol is active. Tab3Reg2=0,1,0x7235 Tab3Reg2Text=This specifies the unit ID used to identify the meter during communications. Tab3Reg3=1,1,0x7A4E Tab3Reg3Text=This specifies the baud rate used during serial communications. Tab4=Ethernet Tab4Type=2 Tab4Text=Allows you to modify the Ethernet communication settings. Tab4Buttons=1 Tab4Button1Label=Edit Tab4Button1=0,4 Tab4Registers=6 Tab4Reg1=3,1,0x1348 Tab4Reg1Text=This specifies the TCP/IP Ethernet address. Tab4Reg2=3,1,0x1349 Tab4Reg2Text=This specifies the Ethernet subnet mask. Subnet masks of 0.0.0.0 and 255.255.255.255 are not permitted. Tab4Reg3=3,1,0x134A Tab4Reg3Text=This specifies the gateway address if one is being used. Tab4Reg4=3,1,0x137F Tab4Reg4Text=This specifies the IP address (or the fully qualified domain name if DNS is active) of the SMTP Server. Tab4Reg5=4,1,0x477F Tab4Reg5Text=This specifies the connection timeout for the SMTP Server. Tab4Reg6=1,3,0x7EBD Tab4Reg6Text=Specifies whether to allow configuration through WebServer interface. [3rd Party Protocols] DefaultDisplayGroups=6 DefaultDisplayGroup1=1 DefaultDisplayGroup2=2 DefaultDisplayGroup3=3 DefaultDisplayGroup4=4 DefaultDisplayGroup5=5 DefaultDisplayGroup6=6 TabCount=2 Tab1=Modbus Slave Tab1Type=8 Tab1Manager=0x8F Tab1Text=Allows you to customize the Modbus map used by other 3rd party device to communicate to the meter. Tab1Buttons=1 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Button2Label=Send Tab1Button2=0,13 Tab2=DNP 3.0 Tab2Type=9 Tab2Manager=0xA1 Tab2Manager2=0xA0 Tab2Text=Allows you to customize the DNP 3.0 map used by other 3rd party device to communicate to the meter. Tab2Buttons=1 Tab2Button1Label=Edit Tab2Button1=0,4 [Clock] TabCount=2 Tab1=Timezone Tab1Type=2 Tab1Text=Allows you to program the meter clock settings. Tab1Buttons=2 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Button2Label=TimeSync Tab1Button2=0,7 Tab1Registers=6 Tab1Reg1Label=Timezone Tab1Reg1=5,3,0x722E Tab1Reg1Text=Specifies the difference in hours between the meter's timezone and GMT. Tab1Reg2=1,3,0x7BB8 Tab1Reg2Text=Specifies the type of time synchronization used to update the meter clock. NOTE: Most software transmits time using the UTC format while some DNP masters and GPS may use localtime format. Tab1Reg3=1,3,0x7BB7 Tab1Reg3Text=Specifies the ONLY communication port that time updates would be accepted on. NOTE: Time synchronization signals on other ports will be ignored. Tab1Reg4=1,3,0x7C24 Tab1Reg4Text=Specifies how the meter should maintain clock accuracy between time updates. NOTE: If using GPS synchronization, this register should be set to COMMS. Tab1Reg5=4,3,0x7231 Tab1Reg5Text=Specifies the amount of time the meter clock is moved forward when entering Daylight Savings. NOTE: A value of zero will disable this feature and the clock will not adjust for DST. Tab1Reg6=2,2,0x5B7D,1 Tab1Reg6Text=This displays the present meter localtime based upon the timezone setting set above and any time synchronization signal received on the Time Sync Source. Tab2=DST Settings Tab2Type=2 Tab2Text=Allows you to program the meter Daylight Savings periods. Tab2Buttons=1 Tab2Button1Label=Edit Tab2Button1=0,4 Tab2Registers=2 Tab2Reg1=2,3,0x722F Tab2Reg2=2,3,0x7230 [Demand] TabCount=1 Tab1=Rolling Block Tab1Type=2 Tab1Text=Allows you to program the interval used to compute your rolling demand values. Tab1Buttons=1 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Registers=2 Tab1Reg1=0,1,0x70C4 Tab1Reg1Warning=1 Tab1Reg1Multi=2 Tab1Reg1Label=Number of Sub-intervals Tab1Reg1Text=This specifies the number of sub-intervals in use. Tab1Reg2=4,1,0x70B4 Tab1Reg2Warning=1 Tab1Reg2Multi=3 Tab1Reg2Label=Sub-interval Length Tab1Reg2Text=This specifies the duration of each of the sub-intervals. [Energy Pulsing] TabCount=4 Tab1=kWh Import Tab1Type=2 Tab1Text=Allows you to program kWh imported pulsing via digital outputs. Tab1Buttons=1 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Registers=5 Tab1Reg1=0,1,0x777D Tab1Reg1Text=Specifies the number of imported watt-hours that are accumulated per physical pulse. Tab1Reg2=0,1,0x7773 Tab1Reg2Text=Specifies the minimum time interval in seconds between pulse transitions. NOTE: There is a minimum 50% duty cycle on all pulses. Tab1Reg3=1,1,0x7E7B Tab1Reg3Text=Specifies if the output pulse is a complete pulse or a KYZ transition. Tab1Reg4=1,1,0x7A0B Tab1Reg4Text=Specifies which physical digital output port the pulse occurs on. Tab1Reg5=6,0,0x6274,1 Tab1Reg5Text=Indicates if the kWh imported is overloaded and pulsing to quickly. Tab2=kWh Export Tab2Type=2 Tab2Text=Allows you to program kWh exported pulsing via digital outputs. Tab2Buttons=1 Tab2Button1Label=Edit Tab2Button1=0,4 Tab2Registers=5 Tab2Reg1=0,1,0x777E Tab2Reg1Text=Specifies the number of exported watt-hours that are accumulated per physical pulse. Tab2Reg2=0,1,0x7774 Tab2Reg2Text=Specifies the minimum time interval in seconds between pulse transitions. NOTE: There is a minimum 50% duty cycle on all pulses. Tab2Reg3=1,1,0x7E7C Tab2Reg3Text=Specifies if the output pulse is a complete pulse or a KYZ transition. Tab2Reg4=1,1,0x7A0C Tab2Reg4Text=Specifies which physical digital output port the pulse occurs on. Tab2Reg5=6,0,0x6275,1 Tab2Reg5Text=Indicates if the kWh exported is overloaded and pulsing to quickly. Tab3=kVARh Import Tab3Type=2 Tab3Text=Allows you to program kVARh imported pulsing via digital outputs. Tab3Buttons=1 Tab3Button1Label=Edit Tab3Button1=0,4 Tab3Registers=5 Tab3Reg1=0,1,0x777F Tab3Reg1Text=Specifies the number of imported var-hours that are accumulated per physical pulse. Tab3Reg2=0,1,0x7775 Tab3Reg2Text=Specifies the minimum time interval in seconds between pulse transitions. NOTE: There is a minimum 50% duty cycle on all pulses. Tab3Reg3=1,1,0x7E7D Tab3Reg3Text=Specifies if the output pulse is a complete pulse or a KYZ transition. Tab3Reg4=1,1,0x7A0D Tab3Reg4Text=Specifies which physical digital output port the pulse occurs on. Tab3Reg5=6,0,0x6276,1 Tab3Reg5Text=Indicates if the kVARh imported is overloaded and pulsing to quickly. Tab4=kVARh Export Tab4Type=2 Tab4Text=Allows you to program kVARh exported pulsing via digital outputs. Tab4Buttons=1 Tab4Button1Label=Edit Tab4Button1=0,4 Tab4Registers=5 Tab4Reg1=0,1,0x7780 Tab4Reg1Text=Specifies the number of exported var-hours that are accumulated per physical pulse. Tab4Reg2=0,1,0x7776 Tab4Reg2Text=Specifies the minimum time interval in seconds between pulse transitions. NOTE: There is a minimum 50% duty cycle on all pulses. Tab4Reg3=1,1,0x7E7E Tab4Reg3Text=Specifies if the output pulse is a complete pulse or a KYZ transition. Tab4Reg4=1,1,0x7A0E Tab4Reg4Text=Specifies which physical digital output port the pulse occurs on. Tab4Reg5=6,0,0x6277,1 Tab4Reg5Text=Indicates if the kVARh exported is overloaded and pulsing to quickly. [Analog Outputs] DefaultDisplayGroups=4 DefaultDisplayGroup1=6 DefaultDisplayGroup2=4 DefaultDisplayGroup3=5 DefaultDisplayGroup4=2 TabCount=4 Tab1=Output 1 Tab1Type=4 Tab1Text=Allows you to program analog output configuration information. Tab1Buttons=2 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Button2Label=Unlink Tab1Button2=0,10 Tab1Module=0x0200 Tab1Registers=3 Tab1Reg1=0,1,0x702A Tab1Reg1Text=Specifies the minimum source value that matches the minimum possible analog output signal. Tab1Reg2=0,1,0x7048 Tab1Reg2Text=Specifies the maximum source value that matches the maximum possible analog output signal. Tab1Reg3=1,1,0x799F Tab1Reg3Text=Specifies which physical analog output port the signal occurs on. Tab2=Output 2 Tab2Type=4 Tab2Text=Allows you to program analog output configuration information. Tab2Buttons=2 Tab2Button1Label=Edit Tab2Button1=0,4 Tab2Button2Label=Unlink Tab2Button2=0,10 Tab2Module=0x0201 Tab2Registers=3 Tab2Reg1=0,1,0x702B Tab2Reg1Text=Specifies the minimum source value that matches the minimum possible analog output signal. Tab2Reg2=0,1,0x7049 Tab2Reg2Text=Specifies the maximum source value that matches the maximum possible analog output signal. Tab2Reg3=1,1,0x79A0 Tab2Reg3Text=Specifies which physical analog output port the signal occurs on. Tab3=Output 3 Tab3Type=4 Tab3Text=Allows you to program analog output configuration information. Tab3Buttons=2 Tab3Button1Label=Edit Tab3Button1=0,4 Tab3Button2Label=Unlink Tab3Button2=0,10 Tab3Module=0x0202 Tab3Registers=3 Tab3Reg1=0,1,0x702C Tab3Reg1Text=Specifies the minimum source value that matches the minimum possible analog output signal. Tab3Reg2=0,1,0x704A Tab3Reg2Text=Specifies the maximum source value that matches the maximum possible analog output signal. Tab3Reg3=1,1,0x79A1 Tab3Reg3Text=Specifies which physical analog output port the signal occurs on. Tab4=Output 4 Tab4Type=4 Tab4Text=Allows you to program analog output configuration information. Tab4Buttons=2 Tab4Button1Label=Edit Tab4Button1=0,4 Tab4Button2Label=Unlink Tab4Button2=0,10 Tab4Module=0x0203 Tab4Registers=3 Tab4Reg1=0,1,0x702D Tab4Reg1Text=Specifies the minimum source value that matches the minimum possible analog output signal. Tab4Reg2=0,1,0x704B Tab4Reg2Text=Specifies the maximum source value that matches the maximum possible analog output signal. Tab4Reg3=1,1,0x79A2 Tab4Reg3Text=Specifies which physical analog output port the signal occurs on. [Memory] TabCount=1 Tab1=Status Tab1Type=6 Tab1Warning=1 Tab1Text=Allows you to allocate the meter log memory. Tab1Buttons=1 Tab1Button1Label=Edit Tab1Button1=0,12 Tab1Logs=3 Tab1Log1=0x0800,0x719C,0x71BC,1 Tab1Log1Text=Allows you to control the duration of the specified log. Tab1Log2=0x0B80,0x71E6,0x0000,1 Tab1Log2Label=Event Log Tab1Log2Text=Allows you to control the number of events stored in the event log. Tab1Log3=0x0801,0x719D,0x71BD,1 Tab1Log3Text=Allows you to control the duration of the specified log. Tab1Modules=2 Tab1Module1=0x94,4 Tab1Module2=0x9C,14 Tab1SystemText=Indicates the amount of memory used by system resources in the meter. [EnergyDemand Log] TabCount=2 Tab1=Channels Tab1Text=Allows you to program the Energy/Demand log inputs. Tab1Type=4 Tab1Buttons=2 Tab1Button1Label=Edit Tab1Button1=0,4 Tab1Button2Label=Unlink Tab1Button2=0,10 Tab1Module=0x0800 Tab1Warning=1 Tab1DisplayGroups=3 Tab1DisplayGroup1=7 Tab1DisplayGroup2=1 Tab1DisplayGroup3=2 Tab2=Interval/Depth Tab2Text=Allows you to specify the interval and duration of the log. Tab2Type=2 Tab2Buttons=1 Tab2Button1=0,4 Tab2Button1Label=Edit Tab2Registers=2 Tab2Reg1=4,1,0x71BC Tab2Reg1Warning=1,0x0800 Tab2Reg1Label=Interval length Tab2Reg1Text=This specifies the time interval between log recordings. Tab2Reg2=0,1,0x719C Tab2Reg2Warning=1 Tab2Reg2Text=This specifies the number of recordings the log can hold. [Reports] TabCount=1 Tab1=Meter Info Tab1Type=2 Tab1Text=Allows you to view/store meter information. Tab1Buttons=1 Tab1Button1Label=Display Tab1Button1=0,8 Tab1Registers=4 Tab1Reg1=10,1,0x0F80,EnergyDemand Log Tab1Reg1Text=This shows the meter energy/demand information. Tab1Reg2=10,1,0x1000,Event Log Tab1Reg2Text=This shows the meter event information. Tab1Reg3=10,1,0x3,Meter Configuration Tab1Reg3Text=This reports the meter configuration information. Tab1Reg4=10,1,0x2,Template Comparison Tab1Reg4Text=This reports the differences between a stored template and the meter template.